- A thorough visual inspection of visible elements. Core sampling from foundations, columns, and ceilings for testing.
- Conducting non-destructive tests: ultrasonic waves, Schmidt hammer, half-cell potential, and carbonation depth measurement.
- Testing for chloride and sulfate content in the concrete.
- Excavating four exploratory points for foundations and soil.
- Preparing structural drawings of the building.
- Structural analysis according to the Saudi code.
- A detailed technical report that includes restoration and strengthening plans and a cost table.